Details
-
Type:
Bug
-
Status:
Closed
-
Priority:
Minor
-
Resolution: Fixed
-
Affects Version/s: CMT8.4.1
-
Fix Version/s: CMT8.4.1
-
Component/s: CUBRID Migration Toolkit
-
Labels:None
-
Environment:
CMT8.4.1.0001
Description
1 Create one sequence
create sequence SEQUENCE2
minvalue -9
maxvalue 10
start with -1
increment by 1
cache 10
cycle
order;
2 do migration use one XE
Actual result
It will be warning "CREATE SERIAL "SEQUENCE24" START WITH -1 INCREMENT BY 1 MINVALUE 0 MAXVALUE 10 CYCLE NOCACHE
Error:
Execute: Minimum value is invalid. create serial SEQUENCE24 start with -1 increment by 1 minvalue 0 maxvalue 10 cycle "
Additional:
If we don't use XE,it is ok
Fixed in CMT 8.4.1.0001